On this page
A dry borewell wastes a lot of money. So before a rig arrives, a geophysicist often walks the site with four steel rods, a battery, an ammeter and a voltmeter. The rods go into the ground in a straight line, equally spaced. A current is pushed in through the outer two, and the voltage is read across the inner two. Class 12 current electricity turns those two readings into the resistivity of the ground. This set-up is called the Wenner array.
How does current spread out from a rod pushed into the ground?
Think of one rod as a point where current I enters uniform ground of resistivity ρ. Below the surface the current spreads out evenly in every downward direction, so at distance r it crosses a hemisphere of area 2πr².
Current density: J = I/(2πr²).
Ohm's law in its local form says the electric field is E = ρJ = ρI/(2πr²).
The field falls off as 1/r², just like the field of a point charge, so the potential has the same 1/r form: V = ρI/(2πr), taking V = 0 far away.
Notice the 2π, not 4π. A charge in open space is surrounded by a full sphere, but a rod at the surface only has the half-space below it, because air does not conduct. This is the same spreading of current through soil that makes standing near a struck tree dangerous, as explained in why you should not shelter under a tree in lightning.
What voltage do the middle rods read in a Wenner array?
Label the rods A, M, N, B along the line, each a distance a from the next. Current I enters at A and leaves at B, so B acts as a source of −I. Potentials from separate sources simply add (superposition).
Rod M is a from A and 2a from B: V_M = (ρI/2π)(1/a − 1/2a) = ρI/(4πa).
Rod N is 2a from A and a from B: V_N = (ρI/2π)(1/2a − 1/a) = −ρI/(4πa).
The voltmeter reads ΔV = V_M − V_N = ρI/(2πa).
Turn this round and you get the working formula: ρ = 2πaΔV/I. The US Geological Survey manual on surface geophysics for groundwater, by Zohdy, Eaton and Mabey (USGS, 1974), derives the same result from a general four-electrode equation, and notes that Wenner first proposed the array for prospecting in 1916.
Why use four rods and not two?
Each rod has an unknown contact resistance with the soil around it. If you pushed current through two rods and read the voltage across the same two rods, that unknown contact resistance would be mixed into your answer. The voltmeter on M and N draws almost no current, so the contact resistance at M and N drops almost nothing across it. It is the same idea as using a separate voltmeter across a wire in the resistivity of a wire experiment, except that here the "wire" is the ground and its shape is set by the rod spacing, not by a length and a cross-section.
How do you work out ground resistivity from a Wenner reading?
These field readings are illustrative, chosen to show how a survey is read.
Spacing a = 10 m. I = 0.2 A, ΔV = 0.64 V. Then ρ = 2π × 10 × 0.64 / 0.2 = 201 Ω m.
Check the units. a in metres, ΔV/I in ohms, so 2πa(ΔV/I) is in ohm metres, the unit of resistivity.
Check the potentials. With ρ = 201 Ω m, V_M = ρI/(4πa) = 0.32 V and V_N = −0.32 V, which add up to the 0.64 V you measured.
Spacing a = 5 m. I = 0.2 A, ΔV = 1.60 V. Then ρ = 2π × 5 × 1.60 / 0.2 = 251 Ω m.
Spacing a = 20 m. I = 0.2 A, ΔV = 0.19 V. Then ρ = 2π × 20 × 0.19 / 0.2 = 119 Ω m.
Sanity check. If the ground were uniform at 100 Ω m, the reading at a = 10 m would be ΔV = ρI/(2πa) = 100 × 0.2 / (2π × 10) = 0.318 V. In uniform ground, doubling a halves ΔV and leaves ρ unchanged. Here ρ changes with spacing, so the ground is not uniform.
The answer falls from 251 to 201 to 119 Ω m as the rods spread out. The wider array is feeling more of a deeper, more conductive layer, and in many places that means wetter ground.
Why does spreading the rods wider look deeper?
When a is small, most of the current between A and B stays in the top few metres, so ΔV mostly reflects the topsoil. As a grows, the current lines bulge further down, and the potential at M and N depends more on deeper layers. Stepping a up and plotting the answer against spacing is called a vertical electrical sounding.
Two cautions come straight from the USGS manual:
The number you calculate in layered ground is an apparent resistivity. It can be a crude average of the true layer values, and can even lie above or below all of them. Getting each layer's actual resistivity and thickness needs a curve fit (an inversion), usually done by software.
The popular rule that "depth of probing equals the electrode spacing" is wrong. How deep the current goes depends on the layers themselves, not only on the spacing.
The manual also notes that surveys use a commutated direct current (its direction switched back and forth) or a current below 1 Hz, not a steady one-way current.
What do the resistivity numbers say about water underground?
Most rock grains barely conduct. Current flows through the water held in pores and cracks, so resistivity depends mainly on how much water there is and how salty it is. The USGS manual gives these ranges:
Some clays, and sands soaked in salty water: below about 1 Ω m.
Sand and gravel saturated with fresh water: about 15 to 600 Ω m, depending on the area.
Dry basalt, dry sand and gravel: several thousand Ω m.
So a low reading is not automatically good news. Clay has low resistivity but gives very little water, and salty water is not drinkable. A survey narrows down where to drill; it does not promise a yield. Where the water sits once you find it, and how the water table and aquifers behave, is covered in how a borewell works.
If the steps from J = I/(2πr²) to V = ρI/(2πr) still feel shaky, the Concept Library has current density, resistivity and electric potential explained one idea at a time.
Quick checklist
A point current entering the ground spreads over a hemisphere: V = ρI/(2πr).
Wenner array: four rods equally spaced a apart, current through the outer pair, voltage across the inner pair.
Superposition gives ΔV = ρI/(2πa), so ρ = 2πaΔV/I.
Four rods keep the unknown contact resistance out of the reading.
Wider spacing samples deeper ground, but spacing is not the depth.
The result in layered ground is an apparent resistivity, not one layer's value.
Low resistivity can mean fresh water, salty water or clay, so local knowledge matters.