The mains in your home runs at 50 Hz. The wiring inside an airliner, a fighter jet or a navy ship usually runs at 400 Hz. The reason is one line from Class 12 electromagnetic induction: the transformer emf equation. It says that the faster the flux in an iron core changes, the less iron you need for the same voltage. In an aircraft every kilogram counts, so engineers chose a higher frequency. The same equation also tells you what that choice costs, and why your house could never use it.
What voltage and frequency do aircraft use?
The US military standard for aircraft power, MIL-STD-704F, defines the main AC supply as 115/200 V, three-phase, at a nominal 400 Hz. The 115 V is the phase voltage and 200 V the line voltage (115 × √3 ≈ 200). The same standard also covers variable-frequency systems running from 360 to 800 Hz, which some newer aircraft use because their generators turn at whatever speed the engine runs. The international standard for aircraft electrical systems, ISO 1540, describes the same 115/200 V system at a constant 400 Hz or over a variable range that includes 400 Hz. Ground power carts that plug into a parked aircraft supply the same kind of power. The exact system varies by aircraft type, so treat these as the standard values, not a rule for every plane.
A generator's frequency is f = pN/120, where p is the number of poles and N the speed in rpm. A 4-pole machine at 1,500 rpm gives 50 Hz. To get 400 Hz you can use 8 poles at 6,000 rpm or 4 poles at 12,000 rpm, which suits the fast-turning shaft of a jet engine.
Where does V = 4.44 f N A B come from?
Let the flux in the core be Φ = B_max A sin ωt, where A is the core's cross-section and ω = 2πf. Faraday's law gives the emf in a coil of N turns:
e = N dΦ/dt = N B_max A ω cos ωt
Peak emf = 2πf N A B_max
rms emf = (2π/√2) f N A B_max = 4.44 f N A B_max
The number 4.44 is just 2π/√2 = 4.443. It holds only when the flux is a sine wave. For a square or distorted wave the factor is different.
Now fix V, N and B_max. B_max is set by the iron: push it much past about 1.2 to 1.7 T and the core saturates, the magnetising current shoots up and the transformer overheats. With those three fixed, A = V/(4.44 f N B_max), so A ∝ 1/f. Eight times the frequency needs an eighth of the core's cross-section.
If you want the turns-ratio side of transformers first, see transformers and AC generators: turns ratio, efficiency and losses.
Worked example: how much smaller is a 400 Hz core?
Take a winding of 100 turns that must give 115 V rms, with B_max = 1.2 T. These are illustrative values chosen to make the arithmetic clear.
At 50 Hz: A = 115/(4.44 × 50 × 100 × 1.2) = 115/26,640 = 4.32 × 10⁻³ m² = 43.2 cm², a square about 6.6 cm on a side.
At 400 Hz: A = 115/(4.44 × 400 × 100 × 1.2) = 115/213,120 = 5.40 × 10⁻⁴ m² = 5.4 cm², about 2.3 cm on a side.
Ratio: 43.2/5.4 = 8, exactly the frequency ratio.
Check the units: V/(Hz × T) = V·s/(Wb/m²) = m², because 1 Wb = 1 V·s. Good.
You could instead keep the 43.2 cm² core and cut the turns. At 400 Hz each turn gives 4.44 × 400 × 4.32 × 10⁻³ × 1.2 = 9.2 V instead of 1.15 V, so 12.5 turns would do the job of 100.
Motors and generators shrink for the same reason, since their emf also comes from N dΦ/dt. In an aircraft packed with pumps, fans and electronics, that adds up to a real saving in weight.
Why don't we use 400 Hz for the power grid?
The cost shows up in the wires. A cable has inductance L, and its inductive reactance is X = 2πfL. Eight times the frequency means eight times the reactance. You can see how X grows with f in inductive and capacitive reactance vs frequency graphs.
Take a cable with 1 µH per metre (an illustrative figure; the real value depends on how far apart the conductors are). For 100 m, L = 100 µH.
At 50 Hz: X = 2π × 50 × 10⁻⁴ = 0.031 Ω. At 100 A that drops 3.1 V.
At 400 Hz: X = 2π × 400 × 10⁻⁴ = 0.25 Ω. At 100 A that drops 25 V, more than a fifth of 115 V.
Inside a plane, cable runs are tens of metres, so the drop stays manageable. Across a city, with lines running for kilometres, a 400 Hz grid would lose most of its voltage to reactance. That is why 400 Hz stays inside the aircraft, the ship or the hangar's ground power cart.
Do iron losses get worse at 400 Hz?
Yes. Eddy-current loss per kilogram goes roughly as f² B_max² t², where t is the lamination thickness. Keep B_max and t the same, go from 50 to 400 Hz, and the eddy loss per kilogram rises (400/50)² = 64 times. Hysteresis loss rises roughly in proportion to f, about 8 times.
There is less iron, which helps, but not enough to cancel a factor of 64. So 400 Hz cores use much thinner laminations: since eddy loss goes as t², cutting t by eight brings the f² penalty back down. A designer can also run at a lower B_max, which gives back some of the size saved. The details of eddy and hysteresis losses are in energy losses in a transformer and how each one is reduced.
If the derivation of e = N dΦ/dt still feels shaky, the Concept Library walks through Faraday's law and transformer emf with the reasoning at each step.
What should you remember for exams?
The aircraft is the hook, but the physics is standard Class 12 EMI and AC. A question may give you V, f, N and B_max and ask for the core area, or ask how the area changes if the frequency changes. To check your understanding:
You can derive E_rms = 4.44 f N A B_max from Φ = B_max A sin ωt and e = N dΦ/dt.
You know 4.44 = 2π/√2 and that it holds only for sinusoidal flux.
You can show that A ∝ 1/f when V, N and B_max are fixed, and check that V/(Hz × T) gives m².
You know that X_L = 2πfL rises with frequency, which is why 400 Hz suits short runs only.
You know eddy loss per kilogram scales roughly as f² t², so higher frequency needs thinner laminations.