An electric rice cooker has no clock inside it, at least not the classic kind. You press one lever, and about half an hour later it clicks off on its own, just as the rice is done. What tells it? Boiling water, and a small piece of magnetic ceramic that stops being magnetic when it gets a little too hot. Put latent heat and the Curie temperature together and you have the whole trick.
Why does water keep the rice cooker pot at 100 °C?
While there is liquid water in the pot, the heater's energy goes into turning water into steam, not into raising the temperature. At sea-level pressure water boils at 100 °C, and boiling water cannot get hotter than its boiling point, however long the heater runs. The extra energy leaves as latent heat in the steam.
So the pot settles onto a temperature plateau. The water, the rice and the inside of the pot all sit near 100 °C for many minutes. The pot base under the water runs slightly hotter, because heat has to flow through it from the heater, but it stays close to 100 °C too.
At a hill station the air pressure is lower, so water boils below 100 °C and the plateau is lower. Why that happens is covered in why water boils at a lower temperature in the mountains.
What happens when the water runs out?
The plateau lasts only as long as free water touches the base. Once the rice has absorbed some of the water and the rest has boiled away, nothing is left to soak up the heat as latent heat. Now the same heater power goes into raising temperature, and the base heats up quickly.
That sudden rise is the signal. A US patent for an electric rice cooker, US 4,234,783, describes exactly this: the bottom of the kettle stays at about 100 °C while water remains, and its temperature rises quickly once the water has evaporated. The cooker only needs a switch that opens a few degrees above 100 °C.
How does a magnet switch off a rice cooker?
The classic switch sits in the middle of the heater plate, pressed against the bottom of the pot by a spring. It has two parts:
A small piece of ferrite, a magnetic ceramic, in contact with the pot base so it follows the base temperature.
A permanent magnet below it, on a lever linked to the heater contacts.
When you press the lever, the magnet is pulled up against the ferrite and sticks there. That holds the heater contacts closed against the pull of a spring. TDK, a maker of ferrites, explains the same design in its article on thermal sensors: the magnet stays stuck to the ferrite while cooking goes on, and when the pot base heats up the ferrite loses its magnetism and a spring pulls the magnet away, switching the cooker off.
The physics is the Curie temperature. Above it, a ferromagnetic (or ferrimagnetic) material loses its spontaneous magnetisation and becomes paramagnetic, so a magnet attracts it only very weakly. The basic idea is covered in does heating a magnet destroy its magnetism?, so it is not repeated here. What is special here is that the ferrite's composition is chosen so its Curie temperature sits just above 100 °C. The patent describes the magnetic part losing its magnetic property at a transition temperature higher than 100 °C.
Exact switch temperatures vary between designs and are rarely published. In this post we use 105 °C as a round illustrative value, not a figure for any particular cooker.
How long does each stage take? (worked example)
Illustrative numbers: aluminium pot 0.35 kg (c = 900 J/kg K), uncooked rice 0.30 kg, water 0.60 kg (c = 4,186 J/kg K), heater 500 W, start at 25 °C. For milled rice, a calorimetry study by Yamada in Nippon Nōgeikagaku Kaishi (1984) gives specific heat rising with moisture; at about 14% moisture its equation gives about 1.54 kJ/kg K, so take 1.5 kJ/kg K. Ignore heat lost to the room.
Heat capacity of the load. 0.35 × 900 + 0.30 × 1,500 + 0.60 × 4,186 = 315 + 450 + 2,512 = 3,277 J/K.
Heating to 100 °C. Q = 3,277 × 75 = 245.7 kJ. Time = 245,700/500 = 491 s, about 8.2 minutes.
The plateau. Suppose the rice absorbs 0.36 kg of water and 0.24 kg boils off. Latent heat of vaporisation is about 2,257 kJ/kg, so Q = 0.24 × 2,257 = 541.7 kJ. Time = 541,700/500 = 1,083 s, about 18.1 minutes, all at a steady 100 °C.
After the water is gone. The load is now pot, rice and absorbed water: 315 + 450 + 0.36 × 4,186 = 2,277 J/K. The temperature rises at 500/2,277 = 0.22 K/s.
Reaching the switch. From 100 °C to the illustrative 105 °C is 5 K, which takes about 5/0.22 = 23 s.
Check the units: J/K × K gives J, and J divided by W gives seconds. Check the sense: boiling off just 0.24 kg of water takes more than twice as much energy as heating the whole load by 75 K, which is why the plateau is the longest stage.
In a real cooker the base near the switch dries and heats first, heat leaks to the room, and the switch takes time to warm, so these times are only a guide. The point holds: the temperature sits flat for many minutes, then climbs within seconds once the water is gone.
Why not just use a bimetallic strip?
You can. Irons and many kettles do, as explained in how a bimetallic thermostat works in an iron. A bimetal bends gradually as it warms, so it suits a dial that sets a temperature. The ferrite switch is different: its magnetism collapses over a narrow range near the Curie point, which gives a clean, one-way click. Once released, it stays off until you press the lever again.
Many modern cookers use a thermistor and a microcontroller instead, which lets them run keep-warm and timed modes, as TDK's article notes. The ferrite and magnet switch is the classic design, and the boiling plateau it relies on is the same in both.
If you want to practise more latent-heat and heating-time problems, the Fermi Problem Library has a step-by-step solver that explains the reasoning.
Quick checklist
While liquid water remains, boiling holds the pot near 100 °C (lower at altitude).
Energy on the plateau goes into latent heat: Q = mL.
When the water is gone, the same power raises the temperature quickly.
A ferrite with a Curie point just above 100 °C stops attracting the magnet, and a spring opens the contacts.
Heating time = (Σ mc × ΔT)/P; plateau time = mL/P.
The switch temperature used here, 105 °C, is illustrative; real designs vary.