Machines in factories, test rigs that squeeze concrete, and the controls on aircraft all need to know where something is to a small fraction of a millimetre. A common sensor for this is the LVDT, the linear variable differential transformer. It is three coils on a tube and a loose iron rod inside. Nothing touches, nothing wears, and the whole idea is mutual inductance from your Class 12 chapter on electromagnetic induction.
What is an LVDT and how is it built?
An LVDT has one primary coil in the middle and two identical secondary coils, S₁ and S₂, one on each side. A soft iron (ferromagnetic alloy) core slides along the axis inside the coils, joined by a thin rod to whatever you want to measure. The core is not a magnet. It only guides the magnetic flux.
The primary is fed with an alternating current, usually a few kilohertz. It has to be AC: a steady current makes a steady flux, and a steady flux induces no emf, which is why a transformer does not work on DC. The changing flux from the primary links each secondary and induces an emf in it, e = M dI/dt, where M is the mutual inductance between the primary and that secondary.
The two secondaries are connected in series opposition: the end of S₁ is joined to the end of S₂ so that their emfs subtract. The output is e₂ − e₁.
Why is the output zero at the centre?
With the core exactly in the middle, the arrangement is symmetric. The primary couples equally to S₁ and S₂, so M₁ = M₂, the two emfs are equal, and they cancel. This position is called the null.
Move the core towards S₂. More of the iron now sits inside S₂, so more of the primary's flux links S₂ and less links S₁. M₂ rises and M₁ falls. The emf in S₂ grows, the emf in S₁ shrinks, and the difference is no longer zero.
A simple model that works near the centre is
M₂ = M₀(1 + x/a) and M₁ = M₀(1 − x/a)
where x is the core displacement and a is a length set by the coil geometry. If the primary current has amplitude I and angular frequency ω, each emf has amplitude ωIM, so the output amplitude is
V = ωI(M₂ − M₁) = 2ωIM₀x/a
The output is proportional to x. That straight-line response is what makes the LVDT a measuring instrument rather than just a detector. How M depends on the geometry of two coils is worked out in mutual inductance of coaxial solenoids; here only the change in M matters.
Worked example: how big is the signal?
Take illustrative values: primary current amplitude I = 20 mA at f = 5 kHz, M₀ = 2 mH, a = 10 mm.
Angular frequency. ω = 2πf = 2π × 5000 = 31,416 rad/s.
Each secondary at the centre. ωIM₀ = 31,416 × 0.020 × 0.002 = 1.257 V. Both secondaries carry 1.257 V, but in opposition, so the output is 0 V.
Sensitivity. 2ωIM₀/a = 2 × 1.257 / 0.010 = 251 V per metre, which is 251 mV per mm. Check the units: (rad/s)(A)(H)/m = V/m, since H × A/s = V.
Core moved 0.1 mm. V = 251 × 0.1 = 25.1 mV.
Core moved 1 mm. V = 251 mV, about a quarter of a volt.
Core moved 5 mm. V = 1.26 V. At this point the model says M₁ has dropped to half of M₀, so a real device is near the end of its straight-line range.
Core moved 2 mm. e₂ = 1.257 × 1.2 = 1.508 V and e₁ = 1.257 × 0.8 = 1.005 V, so the output is 0.503 V.
Resolution. If the electronics have 10 µV of noise, the smallest readable movement is 10 µV ÷ 251 V/m = 4.0 × 10⁻⁸ m, about 0.04 µm.
That last number is why the LVDT is used for precise work: with no friction and no sliding contact, the reading is limited by electrical noise, not by mechanics.
What do real LVDTs give?
Manufacturers quote sensitivity per volt of excitation, because the output scales with the drive. TE Connectivity's E Series LVDT datasheet lists 94.5 mV/V/mm for its ±2.54 mm model and 18.1 mV/V/mm for its ±50.8 mm model, tested with 3 V rms at 2.5 kHz. At 3 V that is 94.5 × 3 = 284 mV per mm for the short model and 18.1 × 3 = 54 mV per mm for the long one. The same sheet gives a maximum non-linearity of ±0.5% of full range for most models.
So our illustrative 251 mV per mm is the right size for a short-stroke LVDT. Longer strokes trade sensitivity for range. The sheet also notes that its figures hold at the test frequency, since sensitivity changes with excitation frequency.
How does an LVDT know which way the core moved?
Look at the amplitude alone. A core 2 mm to the right gives 0.503 V. A core 2 mm to the left gives e₁ = 1.508 V and e₂ = 1.005 V, so e₂ − e₁ = −0.503 V. The size is the same: a meter reading only amplitude shows a V-shaped graph and cannot tell left from right.
The minus sign is the answer. A negative amplitude for a sine wave means the output is turned through 180°. On one side of the null the output is in phase with the excitation reference, and on the other side it is in antiphase. A phase-sensitive detector multiplies the output by the reference signal and averages it, which gives a DC voltage that is positive on one side and negative on the other. The V becomes a straight line through zero, as in the graph above.
How is it different from other displacement sensors?
A strain gauge, as in how a digital weighing scale works, changes resistance when it is stretched. It must be glued to the part, it measures tiny strains, and it needs a bridge circuit. An LVDT measures a movement of millimetres or centimetres directly, and the core can move freely through the bore without touching anything. That is why it survives millions of cycles, works in oil or at high temperature in sealed designs, and is used where a sliding potentiometer would wear out.
To see how the secondary voltage follows the coupling in an ordinary transformer, try the transformer turns ratio simulation. For more induction numericals like the one above, the Fermi Problem Library has a step-by-step solver that explains the reasoning.
Quick checklist
One primary, two secondaries in series opposition, a soft iron core that slides.
The primary needs AC; a steady current induces nothing.
At the centre M₁ = M₂ and the output is zero (the null).
Near the centre, V = 2ωIM₀x/a, proportional to displacement.
Example: 251 mV per mm, 0.503 V at 2 mm, about 0.04 µm resolution with 10 µV noise.
Amplitude gives distance; phase (0° or 180°) gives direction.
Real sensitivities are quoted in mV/V/mm at a stated test frequency.