On this page
Wrap something hot in insulation and it loses less heat. That is true for a flat wall, a thermos flask and a thick steam pipe. It is not always true for a thin wire. Put a thin layer of PVC on a bare copper wire and the wire can lose more heat than before, not less. The radius at which this stops being true is called the critical radius of insulation, and it is a neat test of whether you really understand thermal resistance.
Why can insulation increase heat loss from a thin wire?
For a flat slab, adding insulation only adds resistance. The area that heat flows through does not change. A cylinder is different. As you add insulation, the outer surface gets bigger, and a bigger surface hands heat to the air more easily.
So two things happen at once when the outer radius grows:
Conduction resistance of the insulation goes up, because the heat has a longer path through a poor conductor.
Convection resistance at the surface goes down, because there is more surface area touching the air.
For a thick pipe, the first effect wins from the start. For a thin wire, the second effect wins at first, and the total resistance falls. Why woollen clothes or a thermos flask keep heat in is about trapping still air in a layer; this post is about what the geometry of a cylinder does to that picture.
What is the formula for the critical radius of insulation?
Take a wire of radius rᵢ wrapped in insulation of thermal conductivity k out to an outer radius rₒ. The air outside has a heat transfer coefficient h. Per metre of length, the two resistances in series are:
Conduction through the insulation: ln(rₒ/rᵢ) / 2πk
Convection from the outer surface: 1 / 2πrₒh
The heat loss per metre for a temperature difference ΔT is
q = ΔT ÷ [ln(rₒ/rᵢ)/2πk + 1/2πrₒh]
Differentiate the total resistance with respect to rₒ and set it to zero:
1/(2πk rₒ) − 1/(2πh rₒ²) = 0, which gives rₒ = k/h.
This is the critical radius, rc = k/h. The second derivative is positive there, so the total resistance is a minimum and the heat loss is a maximum. Below rc, adding insulation increases heat loss. Above rc, adding insulation reduces it.
Check the units: k in W/m K divided by h in W/m² K gives metres. Good.
What is the critical radius for a PVC-coated copper wire?
You need two numbers. For k, a manufacturer's datasheet for rigid PVC from APSO lists 0.16 W/m K. Cable PVC is a softer, plasticised grade whose value depends on the recipe, so treat 0.16 as approximate. For h, we use 10 W/m² K as a round illustrative value for still air. Real values for a thin hot wire, including radiation, can be noticeably higher, and we test that below.
rc = k/h = 0.16 ÷ 10 = 0.016 m = 16 mm.
That is far larger than any household wire, so every house wire sits on the rising side of the curve.
Worked example: how much more current can a sheathed wire carry?
Take a 2.5 mm² copper conductor kept 40 K above the surrounding air.
Wire radius. Area πrᵢ² = 2.5 × 10⁻⁶ m², so rᵢ = √(2.5 × 10⁻⁶ ÷ π) = 0.89 mm.
Bare wire loss. q = h × 2πrᵢ × ΔT = 10 × 2π × 8.92 × 10⁻⁴ × 40 = 2.24 W per metre.
With 0.7 mm of PVC (rₒ = 1.6 mm). Conduction: ln(1.6/0.892) ÷ (2π × 0.16) = 0.581 K m/W. Convection: 1 ÷ (2π × 0.0016 × 10) = 9.95 K m/W. Total 10.53 K m/W, so q = 40 ÷ 10.53 = 3.80 W/m. That is 1.70 times the bare loss.
Why that means more current. In steady state the I²R heating equals the heat lost. The copper's resistance per metre is the same with or without the sheath, so for the same temperature rise, I² ∝ q. The sheathed wire can carry √1.70 = 1.30 times the current: about 30% more.
Push the numbers further and the curve keeps rising.
rₒ = 3 mm: 6.14 W/m, 2.7 times the bare wire.
rₒ = 16 mm (the critical radius): 10.3 W/m, 4.6 times the bare wire. This is the peak.
rₒ = 60 mm: 8.99 W/m. Now extra insulation reduces the loss, but slowly.
What if h is really 20 W/m² K? Then rc = 8 mm, the bare wire loses 4.48 W/m and the 1.6 mm sheath gives 7.20 W/m, a ratio of 1.61, so the wire still carries about 27% more current. The exact figure moves; the conclusion does not.
Why does lagging still work on a steam pipe?
Now take a steel steam pipe of outer radius 50 mm lagged with glass wool. A glass wool pipe insulation datasheet gives about 0.032 W/m K at a mean temperature of 23 °C, rising as it gets hotter, so we use a round 0.04 W/m K for a hot pipe. With h = 10 W/m² K:
rc = 0.04 ÷ 10 = 4 mm. The pipe, at 50 mm, is already far past it.
Bare pipe at 100 K above the air: q = 10 × 2π × 0.05 × 100 = 314 W/m.
With 25 mm of lagging (rₒ = 75 mm): conduction ln(75/50) ÷ (2π × 0.04) = 1.613 K m/W, convection 1 ÷ (2π × 0.075 × 10) = 0.212 K m/W, total 1.825 K m/W, so q = 100 ÷ 1.825 = 55 W/m.
The loss drops to under a fifth. For large objects, insulation behaves the way you expect. The surprise is only for thin ones: wires, thin tubes and small pipes in still air.
Is PVC on wires there to cool them?
No. The sheath is there for electrical safety: it stops you touching live copper and stops wires shorting against each other. The extra cooling is a side effect, and you should not read it as a design rule. Real current ratings depend on how cables are bunched, enclosed in conduit and laid, and PVC softens if it gets too hot. The conductor choice itself is covered in why copper is used in electric wires, and the k value used here is what the Lee's disc method measures for a flat sample.
To see how the two resistances trade off as rₒ changes, work a few variations in the Fermi Problem Library, a step-by-step solver that explains the reasoning.
Quick checklist
Cylinder: conduction resistance ln(rₒ/rᵢ)/2πkL rises with rₒ; convection resistance 1/2πrₒhL falls.
Critical radius rc = k/h, where heat loss is a maximum.
Bare radius below k/h: thin insulation increases heat loss.
Bare radius above k/h: insulation reduces heat loss, as for steam pipes.
Same temperature rise means I² ∝ q, so current scales as √q.
h for still air is an estimate; quote rc as approximate.