On this page
Join a copper wire and an iron wire at both ends, keep one junction in ice and heat the other. A millivoltmeter in the loop shows a small emf that grows as the hot junction warms. Keep heating and something odd happens: the reading stops growing, starts to fall, drops to zero and then reverses. The temperature where it peaks is the neutral temperature, and the one where it returns to zero is the temperature of inversion. Both are standard JEE questions, and both come from one curve.
Why is a thermocouple's emf not a straight line?
The simple model of the Seebeck effect says emf = S × Δθ, with S a constant for the pair. That model and its history are in Thomas Seebeck and electricity from a temperature gap. It works over small ranges, but S is not really constant. It changes with temperature, and for many metal pairs it falls steadily as the hot junction gets hotter.
With the cold junction at 0 °C and the hot junction at θ, a good approximation over a limited range is a parabola:
E = aθ + ½bθ²
Here a and b are constants for the pair of metals. Differentiate it:
dE/dθ = a + bθ
This slope is the thermoelectric power (the S of the simple model at that temperature). If b is negative, the slope shrinks as θ rises, reaches zero, and then turns negative. That is the whole story of the turning curve.
What are the neutral and inversion temperatures?
Neutral temperature, θn. The emf is largest where the slope is zero: a + bθn = 0, so θn = −a/b. It depends only on a and b, so only on the two metals. Moving the cold junction does not change it.
Temperature of inversion, θi. With the cold junction at θc, the emf is E = a(θ − θc) + ½b(θ² − θc²). Factor out (θ − θc): E = (θ − θc)[a + ½b(θ + θc)]. Besides the trivial zero at θ = θc, E is zero when θ + θc = −2a/b = 2θn. So θi = 2θn − θc.
A neat symmetry. The neutral temperature sits exactly halfway between the cold junction and the inversion temperature: θn = (θi + θc)/2.
How do you find the peak emf and the turning points? A worked example
Exact constants for copper and iron vary with the purity of the metals and between books, so this example uses illustrative round values: a = 13.5 µV/°C and b = −0.05 µV/°C², with the cold junction at 0 °C.
Neutral temperature. θn = −a/b = 13.5 ÷ 0.05 = 270 °C.
Peak emf. E = 13.5 × 270 + ½(−0.05)(270)² = 3645 − 1822.5 = 1822.5 µV ≈ 1.82 mV. Check units: µV/°C × °C and µV/°C² × °C² both give µV.
Inversion temperature. θi = 2 × 270 − 0 = 540 °C. Check: 13.5 × 540 − 0.025 × 540² = 7290 − 7290 = 0.
A few points on the curve. E = 1.10 mV at 100 °C, 1.70 mV at 200 °C, 1.82 mV at 270 °C, 1.70 mV at 340 °C, 1.10 mV at 440 °C and −0.90 mV at 600 °C.
One reading, two temperatures. Set E = 1100 µV and solve 0.025θ² − 13.5θ + 1100 = 0. The roots are θ = 100 °C and θ = 440 °C, placed symmetrically 170 °C either side of the neutral temperature. A single reading of 1.10 mV cannot tell you which.
Move the cold junction to 20 °C. Now E = f(θ) − f(20), where f(20) = 270 − 10 = 260 µV. The neutral temperature is still 270 °C, but the peak drops to 1822.5 − 260 = 1562.5 µV ≈ 1.56 mV, and inversion moves to 2 × 270 − 20 = 520 °C.
For more problems like this, with a different pair of metals or a cold junction that is not at zero, the Fermi Problem Library has a step-by-step solver that explains the reasoning.
What happens past the temperature of inversion?
The emf changes sign, so the current in the loop reverses direction. The junctions have not stopped working, and nothing has broken; above the neutral temperature the slope a + bθ is negative, and by θi the emf lost above θn has cancelled all the emf gained below it.
There is a link to the reverse effect too. The heat absorbed or given out when current crosses a junction (the effect described in Jean Peltier and cooling at a junction of two metals) is proportional to the difference in thermoelectric power of the two metals at that junction's temperature. At the neutral temperature that difference is zero, so a junction held there neither heats nor cools when a current passes through it.
How close is the parabola to real copper and iron?
The parabola is an approximation that fits only a limited range, and published values for copper–iron differ from book to book. You can make a rough check from the NIST ITS-90 thermocouple tables. Type J is iron against a copper–nickel alloy, and type T is copper against a copper–nickel alloy. Subtracting the type T table from the type J table cancels the alloy, roughly, and leaves an iron-against-copper emf. Done in python, that difference rises to about 1.54 mV near 245 °C, is about 1.53 mV at 270 °C, and falls to about 0.98 mV by 400 °C (the end of the type T table).
That matches the shape and size of the illustrative curve. It is only a rough check: the copper–nickel legs of the two types are each made to match their own table and need not be the same alloy. So treat a quoted copper–iron neutral temperature as approximate, and read real thermocouples from tables, not from a parabola.
Why don't real thermometers use a copper–iron pair?
A thermometer needs one temperature for each reading. A copper–iron couple gives two readings the same emf across its peak, and its slope near the peak is close to zero, so it is least sensitive just where you might want it.
Practical thermocouples use metal pairs whose emf keeps rising across the whole working range. The NIST type K table (a nickel–chromium alloy against a nickel–aluminium alloy) reads 4.096 mV at 100 °C, 20.644 mV at 500 °C and 41.276 mV at 1000 °C. That is about 41 µV per °C throughout, close to a straight line, so a reading maps to one temperature. Another way to read temperature electrically, through a wire's resistance, is in temperature coefficient of resistance.
Quick checklist
E = aθ + ½bθ² with the cold junction at 0 °C; b is negative for pairs that turn back.
Neutral temperature: dE/dθ = 0, so θn = −a/b. It depends only on the metals.
Inversion temperature: θi = 2θn − θc. It depends on the cold junction.
The peak emf is E at θn; equal readings sit symmetrically either side of θn.
Past inversion, the emf and the current reverse.
The parabola is an approximation; copper–iron values vary between sources.