On this page
You can measure γ for air with a large glass bottle, a hand pump, a tap and a U-tube of water. Pump in a little extra air, let it settle, read the manometer, open the tap for a moment, close it, wait, and read the manometer again. Two heights are all you need. This is the method of Clément and Desormes, and it is a neat exam question because it combines an adiabatic step and a constant-volume step in one setup.
What does the Clément–Desormes experiment measure?
It measures γ = Cp/Cv, the ratio of the gas's heat capacities at constant pressure and constant volume. For air, which is almost all diatomic, kinetic theory predicts 7/5 = 1.40. Why Cp is bigger than Cv in the first place is explained in Mayer's relation and what γ tells you.
There are other ways to get γ. One is to time a piston or ball bouncing on a trapped column of gas, which is worked in the period of a piston oscillating on gas in a cylinder. The Clément–Desormes method needs no timing at all, only two manometer readings.
How is the experiment done?
The procedure below follows a standard teaching-lab write-up of the method, Cenco Physics' Clément and Desormes lesson plan, used in a university thermodynamics lab.
Pump and settle. Pump a little air into the bottle and close the tap. Pumping warms the gas, so wait until it is back at room temperature. The water in the U-tube shows a difference h₁ between its two sides. The pressure inside is P₁ = P₀ + ρgh₁, where P₀ is atmospheric pressure.
Open the tap briefly. Some air rushes out until the pressure inside falls to P₀. This happens so fast that there is no time for heat to flow in from the glass, so the gas left inside expands adiabatically. It has done work pushing the escaping air out, so it cools.
Close and wait. With the tap shut, the volume is fixed. The cool gas slowly warms back to room temperature and its pressure rises to P₂ = P₀ + ρgh₂. Read h₂.
The first and last states are at the same temperature (room temperature). Only the middle state is colder. That is the key to the whole method.
How do you get γ from h₁ and h₂?
Follow one fixed parcel of gas: the gas that stays in the bottle throughout. Call its volume V₁ in state 1. In states 2 and 3 it fills the whole bottle, volume V₀.
Step 1 to 2 is adiabatic: P₁V₁^γ = P₀V₀^γ. The PV^γ rule is the same one used in finding the temperature after an adiabatic compression.
States 1 and 3 have the same temperature, so Boyle's law links them: P₁V₁ = P₂V₀.
Eliminate the volumes. From step 2, V₁/V₀ = P₂/P₁. Put that into step 1: (P₂/P₁)^γ = P₀/P₁.
Take logs: γ = ln(P₁/P₀) / ln(P₁/P₂).
When the extra pressures are small, use ln(1 + x) ≈ x. Then ln(P₁/P₀) ≈ ρgh₁/P₀ and ln(P₁/P₂) ≈ ρg(h₁ − h₂)/P₀, and:
γ ≈ h₁/(h₁ − h₂).
The short form needs h₁ to be small compared with atmospheric pressure written as a height of water, which is about 10.3 m. A reading of 20 cm is about 2% of that, so the short form is good to a few parts in a thousand.
Worked example: h₁ = 20.0 cm and h₂ = 5.7 cm
Take water in the manometer, ρ = 1,000 kg/m³, g = 9.81 m/s² and P₀ = 101,325 Pa.
Short form. γ ≈ 20.0 / (20.0 − 5.7) = 20.0 / 14.3 = 1.399.
Pressures for the log form. ρgh₁ = 1,000 × 9.81 × 0.200 = 1,962 Pa, so P₁ = 103,287 Pa. ρgh₂ = 1,000 × 9.81 × 0.057 = 559 Pa, so P₂ = 101,884 Pa.
Log form. γ = ln(103,287/101,325) / ln(103,287/101,884) = 0.01918 / 0.01368 = 1.402.
Check. Both forms give 1.40, the value expected for a diatomic gas. γ has no units, as it should.
What h₂ would give exactly 1.40? From the log form, h₂ = 5.68 cm. From the short form, h₂ = 20.0 × (1 − 1/1.4) = 5.71 cm.
Now see how sensitive the method is. Using the short form:
h₂ = 5.8 cm gives 20.0/14.2 = 1.41.
h₂ = 5.0 cm gives 20.0/15.0 = 1.33.
A change of only a few millimetres in h₂ moves γ a long way, because γ depends on the small difference h₁ − h₂.
How much does the gas cool, and how much escapes?
Start at 300 K. For the adiabatic step, T₂ = T₁(P₀/P₁)^((γ−1)/γ) = 300 × (101,325/103,287)^(0.4/1.4) = 298.4 K. The gas cools by only about 1.6 K. You can check this against step 3: at fixed volume P ∝ T, so T₂ = 300 × P₀/P₂ = 300 × 101,325/101,884 = 298.4 K, the same answer.
The fraction of gas that stays in is V₁/V₀ = (P₀/P₁)^(1/γ) = 0.986, so only about 1.4% of the air leaves. A small puff and a cooling of under 2 K are enough for the measurement.
Why can the result come out wrong?
The method rests on step 2 being truly adiabatic, and that sets up a conflict.
Tap open too long. While the gas sits at P₀, heat starts to flow in from the glass. The gas warms at constant pressure, so a little more air leaves before you close the tap. Less cooling then has to be undone, h₂ comes out smaller, and γ = h₁/(h₁ − h₂) comes out low.
Tap closed too soon. The pressure has not quite reached P₀, so h₂ comes out too large and γ too high.
Not waiting at steps 1 and 3. If the gas is not back at room temperature, the Boyle's law link between states 1 and 3 fails.
This is the main source of error in the experiment, and it is why repeated runs are averaged. To see how adiabatic and constant-volume steps look on a P–V diagram, the Simulation Lab has interactive simulations for ideas that are easier to see than read.
Quick checklist
Pump, wait, read h₁; open the tap briefly; close, wait, read h₂.
States 1 and 3 are at room temperature; state 2 is colder.
Step 1 to 2 is adiabatic; step 2 to 3 is at constant volume.
Exact: γ = ln(P₁/P₀)/ln(P₁/P₂). Small pressures: γ ≈ h₁/(h₁ − h₂).
h₁ = 20.0 cm, h₂ = 5.7 cm gives γ = 1.40 for air.
The air cools by about 1.6 K and only about 1.4% escapes.
A tap left open too long makes γ low; one closed too soon makes it high.