On this page
Slice an ordinary induction motor's stator along one side and flatten it. You get a row of coils whose magnetic field travels in a straight line instead of going round. Put that row under a train, lay an aluminium plate along the track, and the travelling field drags the plate, and so the train, along with it. This is a linear induction motor. It uses the same two ideas as a three-phase induction motor in a factory pump: a moving field from three-phase AC, and currents induced in a conductor that lags behind it.
How does a linear induction motor work?
In a rotary induction motor, three-phase currents in the stator coils make a magnetic field that turns round at a steady speed. That idea, and why the rotor always turns a little slower than the field, is explained in how a rotating magnetic field turns a motor.
Now unroll the stator. The same three-phase windings, laid in a straight line, give a field pattern of alternating north and south poles that slides steadily along the line. In the usual railway layout the coils (the primary) hang under the train and the track carries the secondary: a long aluminium plate, usually backed with steel to carry the magnetic flux.
As the field sweeps over the plate, it induces eddy currents in the aluminium. By Lenz's law these currents oppose the relative motion between the field and the plate. The plate is fixed to the ground, so the reaction pushes the train. The push is in the direction the field travels, and it exists only while the train moves slower than the field.
How fast does the field travel?
The key length is the pole pitch τ, the distance from the centre of one pole to the centre of the next, north to south. One full cycle of the supply moves the field pattern by one full wavelength of the pattern, which is a north pole plus a south pole, or 2τ. So in one second, at frequency f, the field moves 2τ × f:
v_s = 2τf
This is the synchronous speed, the straight-line version of a rotary motor's 120f/P rpm.
Worked example (illustrative round numbers):
Pole pitch. τ = 0.25 m.
Supply at 50 Hz. v_s = 2 × 0.25 × 50 = 25 m/s, which is 90 km/h.
Lower frequency. The train's power electronics vary f. At 30 Hz, v_s = 15 m/s (54 km/h). At 20 Hz, v_s = 10 m/s (36 km/h).
The speed depends only on τ and f, not on the voltage, so the drive controls speed through frequency.
How do you calculate slip, thrust and losses?
Slip measures how far the train lags the field:
s = (v_s − v)/v_s
The power that crosses the air gap from the coils to the plate, P_gap, divides in a fixed ratio. A fraction s is wasted as heat in the plate's eddy currents, and the rest, (1 − s)P_gap, becomes mechanical power. The thrust is
F = P_gap/v_s
These are the same rules as for a rotary motor, with torque replaced by force and angular speed by linear speed.
Continue the example with the train at 22.5 m/s and 400 kW crossing the gap:
Slip. s = (25 − 22.5)/25 = 0.10, or 10%.
Thrust. F = 400,000/25 = 16,000 N = 16 kN.
Heat in the plate. s × P_gap = 0.10 × 400 kW = 40 kW.
Mechanical power. (1 − s) × P_gap = 360 kW.
Check. F × v = 16,000 × 22.5 = 360,000 W = 360 kW. The two routes agree.
The plate heat grows with slip, so the motor is most efficient close to v_s.
Why does the large air gap cost power factor?
A rotor on precise bearings can spin very close to its stator. A train cannot: its wheels wear, its springs move and its track bends, so the coils must ride well clear of the plate. In a review of linear rail transit in China, Li and co-authors (2016) write that the air gap of a linear motor in rail transit is generally designed in a range from 10 mm to 100 mm, and that linear motors have lower efficiency and power factor than rotary motors.
Here is why, with Ampère's law. To drive a flux density B across a gap of width g, the coils need ampere-turns of about Bg/μ₀ for that gap. Take illustrative values: B = 0.5 T, a rotary gap of 0.6 mm and a train gap of 12 mm.
Rotary gap. 0.5 × 0.0006/(4π × 10⁻⁷) ≈ 240 ampere-turns.
Train gap. 0.5 × 0.012/(4π × 10⁻⁷) ≈ 4,800 ampere-turns.
Ratio. 12/0.6 = 20 times as much magnetising current for the same field.
Magnetising current does no work: it lags the voltage by 90° and only sets up the field. When it is a large part of the total current, the supply current falls well out of step with the voltage. That is a low power factor. More current also means more heat in the coils, so efficiency falls too. Designers soften this with a lower B and a longer pole pitch, but the penalty remains. The aluminium plate itself is non-magnetic, so its thickness adds to the magnetic gap as well.
A second loss has no rotary equivalent. A linear motor has a front and a back, and where it arrives over fresh plate or leaves it, the induced currents must build up or die away. These end effects reduce thrust and add loss, so the rotary-motor formulas above are only approximate for a real linear motor.
Which trains use linear induction motors?
Tokyo's Toei Ōedo Line uses this iron-wheel type, with a reaction plate laid between the rails, according to the Tokyo Metropolitan Government. Because the motor is a flat slab under the floor, the cars sit lower, and the same page notes the tunnel cross-section is about half that of earlier Toei lines. The Li review describes Guangzhou Metro Line 4 as China's first linear metro.
The push does not depend on wheel grip, and the Tokyo page credits the system with smooth running on sharp curves and steep slopes. The price is the extra gap loss above.
Do not mix this up with high-speed maglev. Maglev systems such as the Transrapid use a linear synchronous motor, whose field locks onto magnets on the vehicle with no slip, as noted in how maglev trains float. A linear induction motor need not levitate at all.
To watch a travelling field drag a conductor at different slips, try the Simulation Lab. For practice with slip and air-gap power, the Fermi Problem Library has a step-by-step solver that explains the reasoning.
Quick checklist
A linear induction motor is an induction motor unrolled flat: coils on the train, an aluminium plate on the track.
Synchronous speed v_s = 2τf; τ = 0.25 m at 50 Hz gives 25 m/s (90 km/h).
Slip s = (v_s − v)/v_s; thrust F = P_gap/v_s; plate heat = sP_gap; mechanical power = (1 − s)P_gap.
Check by F × v: 16 kN × 22.5 m/s = 360 kW.
A 20 times larger gap needs about 20 times the magnetising ampere-turns for the same B, which lowers power factor and efficiency.
Most linear induction motor trains run on wheels; high-speed maglev uses linear synchronous motors.