On this page
Look closely at someone's eye and you can see a tiny, bright reflection of a window or a lamp on the front of it. That reflection is not just pretty. The front surface of the cornea is curved like a small convex mirror, and the size of the reflection tells you how strongly it is curved. A keratometer is an instrument that measures exactly that. It is a direct use of the mirror formula you learn in Class 10 and Class 12, and this post works through the numbers.
This is a physics explainer, not medical advice. Eye measurements are taken and interpreted by an eye doctor.
How does a keratometer measure the curvature of the cornea?
The tear film on the front of the cornea reflects a small part of the light that falls on it. Because the surface bulges outwards, it behaves as a convex mirror. A convex mirror always forms a virtual, upright, smaller image behind its surface; the reason is explained in why a convex mirror always forms a virtual, diminished image.
The keratometer places an illuminated target, called the mires, of known size h at a known distance u in front of the eye. An optical system inside the instrument measures the size h′ of the mires' reflected image. A strongly curved cornea (small radius R) is a stronger mirror and gives a smaller image. A flatter cornea gives a larger one. From h, u and h′ you can work back to R.
How do you get the radius from the image size?
For a spherical mirror, the focal length is f = R/2. Using the New Cartesian sign convention covered in the sign convention for spherical mirrors, a convex mirror has f = +R/2 and a real object has u negative. Working with sizes only (magnitudes), the mirror formula 1/v + 1/u = 1/f gives the magnification:
m = h′/h = f/(u + f)
where u here is the object distance as a positive number. Put f = R/2 and solve for R:
R = 2um/(1 − m)
Because m is small (about 0.05 for a cornea), many textbooks shorten this to R ≈ 2um = 2uh′/h. That shortcut ignores f in the denominator, and the worked example shows what it costs.
Worked example: a 7.8 mm cornea
Take illustrative instrument values: mires 64 mm apart (h = 64 mm), placed 75 mm in front of the cornea (u = 75 mm). Real keratometers differ in design, so treat these as round example numbers. For the cornea, take R = 7.8 mm. That is a typical size: a 2015 study in PLoS One measured an average front radius of 7.72 mm in untreated eyes.
Focal length. f = R/2 = 3.9 mm.
Magnification. m = f/(u + f) = 3.9/(75 + 3.9) = 3.9/78.9 ≈ 0.0494.
Image size. h′ = mh = 0.0494 × 64 ≈ 3.163 mm.
Image position. With signs, 1/v = 1/f − 1/u = 1/3.9 + 1/75, so v ≈ +3.71 mm. The image is 3.71 mm behind the corneal surface, so it is virtual and upright, as expected for a convex mirror.
Work back. From h′ = 3.163 mm, m = 3.163/64 = 0.04943, and R = 2 × 75 × 0.04943/(1 − 0.04943) ≈ 7.80 mm. Correct.
The shortcut. R ≈ 2uh′/h = 2 × 75 × 3.163/64 ≈ 7.41 mm, about 5% too low, because it treats the image as if it sat at the focus.
Now repeat step 3 for other radii:
R = 7.6 mm: h′ ≈ 3.086 mm
R = 7.7 mm: h′ ≈ 3.125 mm
R = 8.0 mm: h′ ≈ 3.241 mm
A change of 0.1 mm in radius changes the image by only about 0.04 mm. That is why the instrument must measure the image to hundredths of a millimetre. Many keratometers use a doubling prism, which splits the image into two copies, so that small movements of the eye do not spoil the reading.
Why is the reading reported in dioptres?
A doctor wants the cornea's focusing power, not just its radius. The cornea refracts light at two surfaces: air to cornea at the front, and cornea to aqueous humour at the back. A keratometer only measures the front surface. So it converts radius to power with a convention, the keratometric index n = 1.3375:
P = (n − 1)/R = 0.3375/R
For R = 7.8 mm = 0.0078 m, P = 0.3375/0.0078 ≈ 43.3 D.
The number 1.3375 is not the cornea's real refractive index. The same PLoS One study gives the true index as 1.376 and calls 1.3375 the conventional keratometric index. The front surface alone, with the true index, would give 0.376/0.0078 ≈ 48.2 D. The back surface has a negative power, because the aqueous humour behind it (index about 1.336) has a lower index than the cornea. Using the study's average back radius of 6.57 mm, that is (1.336 − 1.376)/0.00657 ≈ −6.1 D. The lower keratometric index is chosen to roughly allow for this back surface using a front-surface measurement only. It is only an approximation: for the study's average untreated eye, 48.7 D at the front and −6.1 D at the back add to about 42.6 D, while 0.3375/0.00772 gives 43.7 D. The study found the convention overestimates most after LASIK or PRK, by about 1.6 D on average.
How does a keratometer detect corneal astigmatism?
If the cornea is curved more steeply in one direction than the other, it is shaped a little like the back of a spoon. The keratometer measures the radius along two perpendicular directions. Suppose it finds 7.8 mm horizontally and 7.6 mm vertically:
Horizontal power. 0.3375/0.0078 ≈ 43.27 D.
Vertical power. 0.3375/0.0076 ≈ 44.41 D.
Difference. 44.41 − 43.27 ≈ 1.14 D of corneal astigmatism.
Readings like these are used, together with other tests, when an eye doctor fits contact lenses or plans refractive surgery. How the corneal radius enters a LASIK calculation is worked in how deep LASIK cuts. If mirror images and sign rules still feel slippery, the Concept Library covers every concept in physics, so you can review spherical mirrors on their own.
Quick checklist
The front of the cornea acts as a convex mirror with f = R/2.
m = f/(u + f), so R = 2um/(1 − m); R ≈ 2uh′/h is about 5% low here.
R = 7.8 mm with 64 mm mires at 75 mm gives an image 3.163 mm across, 3.71 mm behind the surface.
Power is reported as P = 0.3375/R: 43.3 D for 7.8 mm.
1.3375 is a convention; the cornea's true index is about 1.376.
Different radii in two directions mean corneal astigmatism; an eye doctor interprets the readings.