On this page
A float on an arm is the simple way to read a fuel tank, but it has moving parts that can stick. Aircraft tanks often use a sensor with no moving parts at all: a capacitor that the fuel fills. As the fuel rises, the capacitance rises in a straight line, and the gauge turns that into a level. Working out how it does so is a good exercise in cylindrical capacitors, dielectrics and parallel combinations.
What is a capacitive fuel probe?
The probe is two metal tubes, one inside the other, standing upright in the tank. It is a cylindrical capacitor. The gap between the tubes is open at the bottom, so fuel flows in and stands at the same level as in the tank. Above the fuel, the gap holds air.
The two fluids have very different dielectric constants:
Air: K ≈ 1.
Jet fuel: K ≈ 2.1. A table of aviation fuel data in Miljković's paper on capacitive fuel senders lists Jet A and A1 at 2.13 at 20 °C, falling to 2.07 at 60 °C.
So the more of the gap is filled with fuel, the larger the capacitance. The same paper describes the sender as a tubular probe in which the fuel becomes the dielectric and the capacitance is read with an alternating current.
How does capacitance depend on fuel level?
For a cylindrical capacitor of length L, inner radius a and outer radius b, filled with a dielectric of constant K:
C = 2πε₀KL/ln(b/a)
The derivation is in capacitance of spherical and cylindrical capacitors. A partly filled probe is two capacitors side by side. The lower part, of length h, has fuel. The upper part, of length L − h, has air. Both parts share the same two tubes, so they sit across the same potential difference. That makes them parallel, and parallel capacitances add:
C = 2πε₀[Kh + (L − h)]/ln(b/a) = 2πε₀[L + (K − 1)h]/ln(b/a)
This is a straight line in h. The empty probe gives the intercept, and each metre of fuel adds 2πε₀(K − 1)/ln(b/a). Only the excess, K − 1, matters, because the fuel replaces air that was already contributing.
Compare this with a dielectric slab of thickness t placed between capacitor plates, where the slab and the remaining air gap are stacked one after the other in the direction of the field. That is a series arrangement, covered in capacitance with a dielectric slab of thickness t. In the fuel probe the field crosses fuel or air, never both, so the parts are in parallel.
Worked example: how many picofarads per centimetre?
A probe has an inner rod of radius a = 5 mm, an outer tube of inner radius b = 10 mm, and length L = 0.50 m. Take K = 2.1 and ε₀ = 8.854 × 10⁻¹² F/m.
Geometry factor. ln(b/a) = ln 2 = 0.693. So 2πε₀/ln(b/a) = 2π × 8.854 × 10⁻¹²/0.693 = 80.3 pF per metre.
Empty. C = 80.3 × 0.50 = 40.1 pF.
Half full (h = 0.25 m). C = 80.3 × [0.50 + 1.1 × 0.25] = 62.2 pF.
Full (h = 0.50 m). C = 80.3 × [0.50 + 1.1 × 0.50] = 84.3 pF.
Sensitivity. Each centimetre of fuel adds 80.3 × 1.1 × 0.01 = 0.88 pF.
Units check. ε₀ is in F/m, multiplied by a length in metres gives farads. The log is dimensionless.
The whole range from empty to full is only 44 pF. The electronics do not read picofarads off a dial. A typical circuit applies an alternating voltage and measures the current, or makes the probe part of an oscillator whose frequency depends on C, and then converts that into a level.
What happens if there is water in the tank?
Water is denser than fuel, so any water sinks to the bottom of the tank and fills the bottom of the probe first. Water has K ≈ 80, far above fuel.
Take an otherwise empty tank with 1 cm of water in it:
Extra capacitance from the water. 80.3 × (80 − 1) × 0.01 = 63.4 pF.
Total. 40.1 + 63.4 = 103.5 pF.
Compare with fuel. A full tank of fuel adds only 44.1 pF over empty.
What the gauge shows. (103.5 − 40.1)/44.1 = 1.44, so the gauge, calibrated for fuel, reads about 144% full.
One centimetre of water looks like 72 cm of fuel to the probe, which is longer than the probe itself. That is the danger: a gauge with water at the bottom can read high, or full, when the tank holds no fuel at all.
Real water is also slightly conducting because of dissolved salts, so it does not behave as a perfect dielectric. That leaks current across the gap and makes the reading even less reliable. Pilots take fuel samples from the low points of the tanks during the pre-flight check to look for water and sediment, as AOPA's safety tip on fuel sampling describes.
Why does temperature matter for a capacitive gauge?
K changes with temperature. From the same table, Jet A goes from 2.13 at 20 °C to 2.07 at 60 °C. Suppose the gauge assumes K = 2.1 but the fuel in the tank actually has K = 2.07. At a true level of 25.0 cm, the probe sees (2.07 − 1) × 25.0 cm of excess, which the gauge reads as a level of 1.07 × 25.0/1.1 = 24.3 cm. That is a 3% error. Miljković notes that better senders include temperature compensation for this reason.
The same idea of sensing a change in capacitance runs a phone screen too. That application is in how a phone touchscreen knows where you touch; the fuel probe uses it to measure a level instead of a finger.
If cylindrical capacitors or mixed dielectrics are a weak spot, the Concept Library has every concept in physics laid out so you can fill the gap before attempting problems.
Quick checklist
A capacitive fuel probe is a cylindrical capacitor that fills with fuel to the tank level.
Fuel and air parts are in parallel: C = 2πε₀[L + (K − 1)h]/ln(b/a).
C rises linearly with h; the slope depends on K − 1, not K.
Example probe: 40.1 pF empty, 62.2 pF half full, 84.3 pF full, 0.88 pF per cm.
Water (K ≈ 80) at the bottom makes the gauge read far too high: 1 cm reads about 144% full.
K of fuel changes with temperature, so good gauges compensate.