On this page
Every car with a 12 V battery has a small AC generator under the bonnet. The alternator, driven by a belt from the engine, makes three-phase alternating current, and a bridge of six diodes turns it into direct current to charge the battery and run the lights, wipers and electronics. This post works out the frequency an alternator makes, why its rectified output never drops below 86.6% of its peak, and how much power its diodes waste.
Why does a car use an alternator and not a DC generator?
Older cars used a DC dynamo, which rectified its output mechanically with a commutator and brushes that carried the full current. A modern alternator is AC inside, and the rectification is done by semiconductor diodes with no sliding contacts in the main current path. Calling it a "DC generator" is wrong.
Inside an alternator:
The rotor is an electromagnet. A small field current (a few amperes) reaches it through two slip rings. The rotor's iron is shaped into claws, so one coil gives many alternating north and south poles around the rim.
The stator around it carries three sets of windings, 120° apart, usually joined in a star. As the poles sweep past, each winding gets an alternating EMF, and the three EMFs are a third of a cycle apart. Why three phases add up neatly is covered in how Dolivo-Dobrovolsky transmitted three-phase power.
The rectifier is six diodes, two per phase, mounted on finned metal plates.
The regulator measures the output voltage and adjusts the rotor's field current to hold the system near 14 V.
What frequency does a car alternator produce?
For a machine with p pole pairs turning at n revolutions per minute, each winding sees p full cycles per revolution:
f = p × n / 60
Pole counts and pulley ratios vary between designs, so the figures below are illustrative. Many claw-pole rotors have 12 poles (6 pole pairs), and the alternator pulley is often smaller than the crankshaft pulley, so the rotor turns about three times faster than the engine.
Idle at 800 rpm. Rotor speed = 3 × 800 = 2,400 rpm. f = 6 × 2,400 / 60 = 240 Hz.
Engine at 6,000 rpm. Rotor speed = 18,000 rpm. f = 6 × 18,000 / 60 = 1,800 Hz.
The frequency changes with engine speed, unlike the fixed 50 Hz of the mains. That does not matter, because the car never uses the AC directly.
How do six diodes turn three-phase AC into DC?
Call the three phase voltages V_A, V_B and V_C. The bridge has three diodes connected to the positive output and three to the negative output.
On the positive side, only the diode on whichever phase is most positive at that instant conducts.
On the negative side, only the diode on whichever phase is most negative conducts.
So at every instant exactly two diodes carry the current, and the output equals the largest line-to-line voltage at that moment. The output follows the tops of six overlapping half-cycles of line-to-line voltage per AC cycle. Single-phase bridge rectifiers, where the output falls to zero twice a cycle, are covered in half-wave and full-wave rectifiers; the three-phase bridge is the same idea with more phases.
Why is the three-phase ripple only 13.4%?
Each line-to-line voltage takes over as the largest for 60° of the cycle, the part from 30° before its peak to 30° after. The output is lowest at the hand-over points, which are 30° from a peak.
Worked example: an alternator bridge at idle
Minimum of the output. At a hand-over point the output is V_LL,peak × cos 30° = 0.866 V_LL,peak.
Ripple. Peak to peak, the output swings between V_LL,peak and 0.866 V_LL,peak, which is 1 − 0.866 = 13.4% of the peak.
Ripple frequency. There are six peaks per AC cycle, so the ripple frequency is 6f. At idle, 6 × 240 Hz = 1,440 Hz. It is not 2f, which is the single-phase full-wave answer.
Average output. Averaging the 60° cap of a cosine from −30° to +30° gives (3/π) V_LL,peak = 0.955 V_LL,peak. For single-phase full-wave the average is 2/π = 0.637 of the peak, and the output falls all the way to zero.
Winding voltage needed. Suppose the battery needs 14.4 V and each of the two conducting diodes drops about 0.9 V at high current. The bridge must give 14.4 + 2 × 0.9 = 16.2 V on average. So V_LL,peak = 16.2 / 0.955 = 17.0 V, which is 17.0 / √2 = 12.0 V rms line to line.
Diode loss at 100 A. The two conducting diodes waste 2 × 0.9 V × 100 A = 180 W. The battery side gets 14.4 V × 100 A = 1,440 W. Of the 1,620 W leaving the windings, 180 / 1,620 = 11% becomes heat in the diodes.
Units check: V × A = W in step 6, and the percentage in step 2 is a ratio of two voltages, so it has no unit.
That 180 W of heat is why the diode plates are finned and sit in the alternator's own cooling airflow.
What holds the voltage at 14 V?
Not the diodes. They only rectify. The output of an alternator rises with speed, because the EMF in each winding is proportional to the rate at which flux changes.
The regulator holds it steady. When the output voltage climbs above its set point, the regulator reduces the field current in the rotor; when it falls, the regulator increases it. So at high engine speed the rotor runs with a weak field, and at idle with a strong one.
The battery helps too. It sits across the output and behaves like a very large capacitor, soaking up most of the 13.4% ripple before it reaches the electronics.
If you want to see how ripple changes as you go from one phase to three, the Simulation Lab has interactive simulations for ideas that are easier to see than to read.
Quick checklist
A car alternator makes three-phase AC; six diodes rectify it.
f = p × n / 60, with the rotor turning faster than the engine.
At every instant, two diodes conduct and the output is the largest line-to-line voltage.
Output never falls below cos 30° = 0.866 of the peak: 13.4% ripple at 6f.
Average output = (3/π) V_LL,peak = 0.955 V_LL,peak, against 0.637 for single-phase.
Diode loss = 2 × V_diode × I, about 180 W at 100 A.
The regulator controls the rotor's field current; the diodes do not set the voltage.